Service Hotline +49 6055 93752-0

  Find a dealer in your country

Ceiling fan Aerodynamix Eco 112 WE-NB

Product information: "CasaFan Ceiling fan Aerodynamix Eco 112 WE-NB"

CasaFan AERODYNAMIX ECO 112 WE-NB, energy saving ceiling fan, Ø 112 cm, housing white, 3 blades walnut, handmade from layer-glued solid wood, 220-240 V 50 Hz, DC/EC motor 3,4-17 W, remote control incl. (motor 6 speeds, forward/reverse - summer/winter -, light on/off) and wall bracket, opal glass light kit incl. 2 x 40 W E14 , also suitable for ESL, installation also without light kit and with blind cover included) possible, rev. max. 72-191 RPM, distance ceiling - blades 250 mm, installation only on straight ceilings (with optional downrod on sloped ceilings up to 28°), balanced motor and blades, for room sizes up to 16 m², optional blades and longer downrods available

Blade decor: walnut
Blade extras: Interchangeable blades possible
Control: forward/reverse function, remote control included
Housing colour: white
Lighting: Light kit incl., installation without light kit possible
Motor type: ECO motor
No. of blades: 3
No. of speeds: 6 speeds with remote control
Power light kit max. (W): 2 x 40, E14
Power motor max. (W): 11,3
Power motor min. (W): 3,8
Rev. max. (RPM): 191
Size Ø (cm): 112
Specials: energy saving, longer downrods possible, only on straight ceilings
Style: fancy, modern
Voltage (V/Hz): 220-240/50
for rooms up to (m²): 16
Blade decor: walnut
Blade extras: Interchangeable blades possible
Control: forward/reverse function, remote control included
Housing colour: white
Lighting: Light kit incl., installation without light kit possible
Motor type: ECO motor
No. of blades: 3
No. of speeds: 6 speeds with remote control
Power light kit max. (W): 2 x 40, E14
Power motor max. (W): 11,3
Power motor min. (W): 3,8
Rev. max. (RPM): 191
Size Ø (cm): 112
Specials: energy saving, longer downrods possible, only on straight ceilings
Style: fancy, modern
Voltage (V/Hz): 220-240/50
for rooms up to (m²): 16
Manufacturer:
CasaFan GmbH
Senefelderstr. 8
D-63594 Hasselroth
E-Mail: info@ventilator.de
Internet: https://www.ventilator.de

Abmessungen Aerodynamix Eco

25 years limited motor warranty

Performance data 
Motor type:EC/DC
Air flow at highest level (m³/h)5.423
Maximum fan flow rate F (m³/min)90,4
Service value SV ((m³/min)/W)8,0
Air velocity 1.5 m above floor1 (m/s)2,19
RPM (min-1) Level 174
RPM (min-1) Level 298
RPM (min-1) Level 3118
RPM (min-1) Level 4142
RPM (min-1) Level 5176
RPM (min-1) Level 6190
Fan power input P (W) Level 13,8
Fan power input P (W) Level 24,5
Fan power input P (W) Level 35,4
Fan power input P (W) Level 47,0
Fan power input P (W) Level 59,9
Fan power input P (W) Level 611,3
Fan sound power level LW (dB(A))2,3 Level 1< 32
Fan sound power level LW (dB(A))2,3 Level 2< 32
Fan sound power level LW (dB(A))2,3 Level 3< 32
Fan sound power level LW (dB(A))2,3 Level 434,1
Fan sound power level LW (dB(A))2,3 Level 540,8
Fan sound power level LW (dB(A))2,3 Level 648,3
Fan sound pressure level LP - 3 m (dB(A))2,3 Level 1< 15
Fan sound pressure level LP - 3 m (dB(A))2,3 Level 2< 15
Fan sound pressure level LP - 3 m (dB(A))2,3 Level 3< 15
Fan sound pressure level LP - 3 m (dB(A))2,3 Level 415,2
Fan sound pressure level LP - 3 m (dB(A))2,3 Level 520,3
Fan sound pressure level LP - 3 m (dB(A))2,3 Level 627,8


1 The table shows the maximum speed at the highest setting at 1.5 m above the oor in a 3 m high room. This is to help you estimate draughts at head height, sitting under the ceiling fan. This specifcation refers to the highest speed. A fine gradation of the speed with as many steps as possible enables you to have draught-free operation even in winter when returning the warm air that is under the ceiling.

2 Noise measurements were carried out at the VDE Testing and Certification Institute in Offenbach/Main. The lower limit for the laboratory measurement is 32 dB(A) for sound power LW and 15 dB(A) for sound pressure LP -3m.

3 Since many ceiling fans on the market are published with one or the other value, we provide the measured noise values both as sound power LW and sound pressure LP-3m..

 
Title File name File Size Type Date Download
AERODYNAMIX ECO Instruction Manual Bedienungsanleitung_Aerodynamix DE_GB_FR_IT_ES_CZ_NL_PL_v81 3880kb pdf 2024-10-30 09:05
AERODYNAMIX ECO Datasheet Datasheet-AERODYNAMIX-ECO-english 466kb pdf 2024-10-30 09:04
AERODYNAMIX ECO Datasheet A4 Datasheet-AERODYNAMIX-ECO-english-A4 483kb pdf 2024-10-30 09:04
AERODYNAMIX ECO Datenblatt Datenblatt-AERODYNAMIX-ECO-deutsch 2446kb pdf 2024-10-30 09:03
AERODYNAMIX ECO Datenblatt A4 Datenblatt-AERODYNAMIX-ECO-deutsch-A4 2473kb pdf 2024-10-30 09:03

SAFETY INSTRUCTIONS CEILING FANS INSIDE

  • The fan is used to circulate dry room air. It must not be used in machines or in damp, wet, corrosive, flammable or explosive rooms and areas.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Cleaning and maintenance by the user must not be carried out by children without supervision.
  • Children must not play with the appliance.
  • Dispose of the packaging material out of the reach of children. There is a risk of suffocation, e.g. if swallowed!
  • If unusual oscillating movements or noises occur during operation, switch off the fan immediately, secure it against being switched on again and contact the manufacturer, its customer service or a suitably qualified person.
  • Parts of the safety suspension system may only be replaced with original spare parts.
  • The installation of the suspension system and the electrical connection of the appliance must not be carried out by an unqualified person.
  • Before installing, cleaning or servicing the fan, switch off the power by disconnecting the fuse in the fuse box and secure it against being switched on again.
  • The voltage specification on the rating plate must match the local mains voltage.
  • The mains connection to which the fan is connected must comply with the applicable local standards and be installed in accordance with regulations. It must have an earth connection and the fan must be connected to this.
  • The fan may only be operated when fully assembled.
  • Select a safe, non-hazardous installation location where no objects can get caught in the blades.
  • The structure of the ceiling and the fasteners must be able to support 4 times the weight of the fan.
  • All fan blades must be at least 2.30 m from the floor.
  • Keep the fan away from heat sources. The minimum distance from radiant heaters and ovens is 1.5 metres.
  • Do not run the cables over sharp edges and never crush the cables during installation.
  • Maintenance must be carried out once a year. Check the suspension system and its components for damage, e.g. due to corrosion. If the suspension system is damaged, the fan must be taken out of operation and secured against being switched on again. Contact the manufacturer to solve the problem. If your fan has plastic blades, these must be checked for cracks and breaks, particularly near the blade fastening screws. If the blades are damaged, the fan must be taken out of operation and secured against being switched on again. Contact the manufacturer to solve the problem.
  • Once installation is complete, all electrical connections must be checked again to rule out any risk of falling, fire or electric shock.

Accessories

Hotel wall control FB-FNK ECO Hotel B Order number: 86201
only for selected ECO ceiling fans from CasaFan (see product description)

To order this product, please log in here.

Downrod ST 120 WE-AD Order number: 981059
Housing: white
Length: 120 cm
for ceiling fan Aerodynamix Eco

To order this product, please log in here.

Downrod ST 60 WE-AD Order number: 981039
Housing: white
Length: 60 cm
for ceiling fan Aerodynamix Eco