Delivery in 2-3 days
WEE-Reg-Nr.: DE29217367
CasaFan AEROPLAN ECO LG-LG, energy saving ceiling fan, Ø 132 cm, housing light grey, 3 blades light grey, milled from solid wood, 100-240 V 50-60 Hz, DC/EC motor 2,7-19 W, remote control incl. (motor 6 speeds, forward/reverse - summer/winter -, sleep timer) and wall bracket, slow motion speed, rev. max. 30-234 RPM, 2 downrods incl. (100 and 60 mm), distance ceiling - blades 310 mm (270 mm with short downrod), installation on sloped ceilings up to 30°, balanced motor and blades, for room sizes up to 25 m², optional longer downrods available
Blade decor: | light grey |
---|---|
Control: | forward/reverse function, remote control included, sleep timer, slow motion speed |
Housing colour: | light grey |
Motor type: | ECO motor |
No. of blades: | 3 |
No. of speeds: | 6 speeds with remote control |
Power motor max. (W): | 27 |
Power motor min. (W): | 2,7 |
Rev. max. (RPM): | 226 |
Size Ø (cm): | 132 |
Specials: | energy saving, longer downrods possible, suitable for sloped ceilings |
Style: | modern |
Voltage (V/Hz): | 100-240/50-60 |
for rooms up to (m²): | 25 |
Blade decor: | light grey |
---|---|
Control: | forward/reverse function, remote control included, sleep timer, slow motion speed |
Housing colour: | light grey |
Motor type: | ECO motor |
No. of blades: | 3 |
No. of speeds: | 6 speeds with remote control |
Power motor max. (W): | 27 |
Power motor min. (W): | 2,7 |
Rev. max. (RPM): | 226 |
Size Ø (cm): | 132 |
Specials: | energy saving, longer downrods possible, suitable for sloped ceilings |
Style: | modern |
Voltage (V/Hz): | 100-240/50-60 |
for rooms up to (m²): | 25 |
CasaFan GmbH
Senefelderstr. 8
D-63594 Hasselroth
E-Mail: info@ventilator.de
Internet: https://www.ventilator.de
Performance data | |
Motor type: | EC/DC |
Air flow at highest level (m³/h) | 8.581 |
Maximum fan flow rate F (m³/min) | 143,0 |
Service value SV ((m³/min)/W) | 5,4 |
Air velocity 1.5 m above floor1 (m/s) | 2,16 |
RPM (min-1) Level 1 | 30 |
RPM (min-1) Level 2 | 72 |
RPM (min-1) Level 3 | 111 |
RPM (min-1) Level 4 | 150 |
RPM (min-1) Level 5 | 190 |
RPM (min-1) Level 6 | 226 |
Fan power input P (W) Level 1 | 2,7 |
Fan power input P (W) Level 2 | 3,5 |
Fan power input P (W) Level 3 | 5,1 |
Fan power input P (W) Level 4 | 8,4 |
Fan power input P (W) Level 5 | 13,8 |
Fan power input P (W) Level 6 | 26,5 |
Fan sound power level LW (dB(A))2,3 Level 1 | < 32 |
Fan sound power level LW (dB(A))2,3 Level 2 | < 32 |
Fan sound power level LW (dB(A))2,3 Level 3 | < 32 |
Fan sound power level LW (dB(A))2,3 Level 4 | 32,4 |
Fan sound power level LW (dB(A))2,3 Level 5 | 34,1 |
Fan sound power level LW (dB(A))2,3 Level 6 | 34,4 |
Fan sound pressure level LP - 3 m (dB(A))2,3 Level 1 | < 15 |
Fan sound pressure level LP - 3 m (dB(A))2,3 Level 2 | < 15 |
Fan sound pressure level LP - 3 m (dB(A))2,3 Level 3 | < 15 |
Fan sound pressure level LP - 3 m (dB(A))2,3 Level 4 | < 15 |
Fan sound pressure level LP - 3 m (dB(A))2,3 Level 5 | < 15 |
Fan sound pressure level LP - 3 m (dB(A))2,3 Level 6 | < 15 |
1 The table shows the maximum speed at the highest setting at 1.5 m above the oor in a 3 m high room. This is to help you estimate draughts at head height, sitting under the ceiling fan. This specifcation refers to the highest speed. A fine gradation of the speed with as many steps as possible enables you to have draught-free operation even in winter when returning the warm air that is under the ceiling.
2 Noise measurements were carried out at the VDE Testing and Certification Institute in Offenbach/Main. The lower limit for the laboratory measurement is 32 dB(A) for sound power LW and 15 dB(A) for sound pressure LP -3m.
3 Since many ceiling fans on the market are published with one or the other value, we provide the measured noise values both as sound power LW and sound pressure LP-3m..
Your new ceiling fan needs a power supply on the ceiling where it is to be mounted. Since installing additional cables at a later date is often very costly or simply not possible, we have designed all our fans so that they can be exchanged with an existing ceiling light. Below you will find the assignment of the wiring diagrams to the model. Standard is a switched phase or continuous voltage.