Service Hotline +49 6055 93752-0

  Find a dealer in your country

Ceiling fan Classic Flat 75-III MG-EA/BU

Product information: "CasaFan Ceiling fan Classic Flat 75-III MG-EA/BU"

CasaFan CLASSIC FLAT 75-III MG-EA/BU, ceiling fan, Ø 79,2 cm, housing brushed brass, 5 reversible blades antique oak/beech, 220-240 V 50 Hz, motor max. 61 W, 3-speed pull chain switch, forward/reverse - summer/winter - by slide switch, rev. max. 309 RPM, very low profile, distance ceiling - blades 164 mm, very low profile, installation only on straight ceilings, balanced motor and blades, for room sizes up to 6 m², optional interchangeable blades, remote controls, wall controls and light kits available

Blade decor: antique oak, beech
Blade extras: Interchangeable blades possible, reversable blades
Control: forward/reverse function, remote control possible, wall control possible, with pull chain switch
Housing colour: brushed brass
Lighting: Light kit possible
Motor type: AC motor
No. of blades: 5
No. of speeds: 3 speeds with pull-chain switch
Power motor max. (W): 63
Rev. max. (RPM): 315
Size Ø (cm): 79,2
Specials: extra low profile, only on straight ceilings
Style: classic
Voltage (V/Hz): 220-240/50
for rooms up to (m²): 6
Blade decor: antique oak, beech
Blade extras: Interchangeable blades possible, reversable blades
Control: forward/reverse function, remote control possible, wall control possible, with pull chain switch
Housing colour: brushed brass
Lighting: Light kit possible
Motor type: AC motor
No. of blades: 5
No. of speeds: 3 speeds with pull-chain switch
Power motor max. (W): 63
Rev. max. (RPM): 315
Size Ø (cm): 79,2
Specials: extra low profile, only on straight ceilings
Style: classic
Voltage (V/Hz): 220-240/50
for rooms up to (m²): 6
Manufacturer:
CasaFan GmbH
Senefelderstr. 8
D-63594 Hasselroth
E-Mail: info@ventilator.de
Internet: https://www.ventilator.de

Abmessungen Classic Flat 75-III

15 years limited motor warranty

Performance data  
Motor type: AC
Air flow at highest level (m³/h) 3.431
Maximum fan flow rate F (m³/min) 57,2
Service value SV ((m³/min)/W) 0,9
Air velocity 1.5 m above floor1 (m/s) 2,07
RPM (min-1) Level 1 189
RPM (min-1) Level 2 217
RPM (min-1) Level 3 315
Fan power input P (W) Level 1 23,3
Fan power input P (W) Level 2 35,9
Fan power input P (W) Level 3 63,0
Fan sound power level LW (dB(A))2,3 Level 1 39,2
Fan sound power level LW (dB(A))2,3 Level 2 47,8
Fan sound power level LW (dB(A))2,3 Level 3 48,3
Fan sound pressure level LP - 3 m (dB(A))2,3 Level 1 18,7
Fan sound pressure level LP - 3 m (dB(A))2,3 Level 2 27,3
Fan sound pressure level LP - 3 m (dB(A))2,3 Level 3 27,8


1 The table shows the maximum speed at the highest setting at 1.5 m above the oor in a 3 m high room. This is to help you estimate draughts at head height, sitting under the ceiling fan. This specifcation refers to the highest speed. A fine gradation of the speed with as many steps as possible enables you to have draught-free operation even in winter when returning the warm air that is under the ceiling.

2 Noise measurements were carried out at the VDE Testing and Certification Institute in Offenbach/Main. The lower limit for the laboratory measurement is 32 dB(A) for sound power LW and 15 dB(A) for sound pressure LP -3m.

3 Since many ceiling fans on the market are published with one or the other value, we provide the measured noise values both as sound power LW and sound pressure LP-3m..

 

Your new ceiling fan needs a power supply on the ceiling where it is to be mounted. Since installing additional cables at a later date is often very costly or simply not possible, we have designed all our fans so that they can be exchanged with an existing ceiling light. Below you will find the assignment of the wiring diagrams to the model. Standard is a switched phase or continuous voltage.
(Wiring diagram 2 and 8 only required with optional accessories such as remote control, wall switch or light kit)

Deckenventilator-Anschlussplan-1Deckenventilator-Anschlussplan-2Deckenventilator-Anschlussplan-5Deckenventilator-Anschlussplan-8

Title File name File Size Type Date Download
CLASSIC FLAT III Instruction Manual Bedienungsanleitung_FLAT-III_DE_GB_FR_IT_ES_CZ_NL_PL_v80 2683kb pdf 2024-10-31 08:02
CLASSIC FLAT 75 III Datasheet Datasheet-CLASSIC-FLAT-75-III-english 316kb pdf 2024-10-31 15:20
CLASSIC FLAT 75 III Datenblatt Datenblatt-CLASSIC-FLAT-75-III-deutsch 1567kb pdf 2024-10-30 10:23

SAFETY INSTRUCTIONS CEILING FANS INSIDE

  • The fan is used to circulate dry room air. It must not be used in machines or in damp, wet, corrosive, flammable or explosive rooms and areas.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Cleaning and maintenance by the user must not be carried out by children without supervision.
  • Children must not play with the appliance.
  • Dispose of the packaging material out of the reach of children. There is a risk of suffocation, e.g. if swallowed!
  • If unusual oscillating movements or noises occur during operation, switch off the fan immediately, secure it against being switched on again and contact the manufacturer, its customer service or a suitably qualified person.
  • Parts of the safety suspension system may only be replaced with original spare parts.
  • The installation of the suspension system and the electrical connection of the appliance must not be carried out by an unqualified person.
  • Before installing, cleaning or servicing the fan, switch off the power by disconnecting the fuse in the fuse box and secure it against being switched on again.
  • The voltage specification on the rating plate must match the local mains voltage.
  • The mains connection to which the fan is connected must comply with the applicable local standards and be installed in accordance with regulations. It must have an earth connection and the fan must be connected to this.
  • The fan may only be operated when fully assembled.
  • Select a safe, non-hazardous installation location where no objects can get caught in the blades.
  • The structure of the ceiling and the fasteners must be able to support 4 times the weight of the fan.
  • All fan blades must be at least 2.30 m from the floor.
  • Keep the fan away from heat sources. The minimum distance from radiant heaters and ovens is 1.5 metres.
  • Do not run the cables over sharp edges and never crush the cables during installation.
  • Maintenance must be carried out once a year. Check the suspension system and its components for damage, e.g. due to corrosion. If the suspension system is damaged, the fan must be taken out of operation and secured against being switched on again. Contact the manufacturer to solve the problem. If your fan has plastic blades, these must be checked for cracks and breaks, particularly near the blade fastening screws. If the blades are damaged, the fan must be taken out of operation and secured against being switched on again. Contact the manufacturer to solve the problem.
  • Once installation is complete, all electrical connections must be checked again to rule out any risk of falling, fire or electric shock.

Blades

Blade set FLAT 75-III beech/antique oak Order number: 19317

To order this product, please log in here.

Blade set FLAT 75-III walnut/beech Order number: 19397

To order this product, please log in here.

Blade set FLAT 75-III white finish/light grey Order number: 19319

To order this product, please log in here.

Blade set FLAT 75-III used wood oak/colonial oak Order number: 19200

To order this product, please log in here.

Blade set FLAT 75-III used wood oak/maple Order number: 19193

To order this product, please log in here.

Controller

KNX control FANinBOX Order number: 85350
for Smart Home control of non-ECO ceiling fans, up to 3 speeds

To order this product, please log in here.

Hotel wall control FB-FNK-D AC Hotel Order number: 86210

To order this product, please log in here.

Remote control FB-FNK-D LCD Touch (handheld transmitter + receiver) Order number: 85236
for CasaFan ceiling fans

To order this product, please log in here.

Step transformer SCNR5 Order number: 12955
5-speed transformer, 230 V, max. 0,45 A, ony for NON Eco ceiling fans

To order this product, please log in here.

Step transformer SCNRL 5 Order number: 12957
5-speed transformer, 230 V ~ 50 Hz, max. 0,45 A, with illuminated light and ON/OFF switch

To order this product, please log in here.

Wall control ST4-150 II Order number: 85215
4-step speed controller without light switch, motor (max. 100 W)

To order this product, please log in here.

Wall control ST4-150/400 Order number: 85205
4-step speed controller with light switch (max. 400 W), motor (max. 100 W)

To order this product, please log in here.