Delivery in 2-3 days
WEE-Reg-Nr.: DE29217367
CasaFan SafeLine high-performance table/surface-mounted fan for commercial use, 43 W, 220-240 V / 50 Hz, safety grille 350 mm, degree of protection IP54, 2,420 m³/h acc. to. EN 60879, protective grille, housing, frame and base steel with double corrosion protection coating, colour white, 2-pole mains switch, 3 steps by means of encapsulated pressure switch, vertical inclination 130° adjustable, stable design with carrying handle, encapsulated motor with ball bearing, cable 2.5m rubber hose cable for high mechanical load H07RN-F 3 x 1.0 mm² with Schuko plug, certified according to maachinery directive 2006/42/EC Part 1 for commercial use
Air flow max (m³/h): | 2250 |
---|---|
Blade Ø (mm): | 303 |
Cable: | 2,5 m cable H07RN-F G 3 1,0 mm², with Schuko-Plug IPX4 |
Colour: | Two-coat corrosion protection coating, white |
Fan type: | Desk fan, Industrial fan, Surface-mounted fan |
Grille Ø (mm): | 350 |
Material: | metal |
No. of speeds: | 3 |
Power motor max. (W): | 43 |
Rev. max. (RPM): | 1360 |
Specials SV: | IP54, Safety class I, for commercial use |
Voltage (V/Hz): | 220-240/50 |
Air flow max (m³/h): | 2250 |
---|---|
Blade Ø (mm): | 303 |
Cable: | 2,5 m cable H07RN-F G 3 1,0 mm², with Schuko-Plug IPX4 |
Colour: | Two-coat corrosion protection coating, white |
Fan type: | Desk fan, Industrial fan, Surface-mounted fan |
Grille Ø (mm): | 350 |
Material: | metal |
No. of speeds: | 3 |
Power motor max. (W): | 43 |
Rev. max. (RPM): | 1360 |
Specials SV: | IP54, Safety class I, for commercial use |
Voltage (V/Hz): | 220-240/50 |
CasaFan GmbH
Senefelderstr. 8
D-63594 Hasselroth
E-Mail: info@ventilator.de
Internet: https://www.ventilator.de
SAFETY INSTRUCTIONS SUMMER FANS IP44, IP54
- The fan is used to circulate air. It must not be used in corrosive, flammable or explosive atmospheres or in machinery.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
- Cleaning and maintenance by the user must not be carried out by children without supervision.
- Children must not play with the appliance.
- Dispose of the packaging material out of the reach of children. There is a risk of suffocation, e.g. if swallowed!
- Check the mains cable for damage and the protective grille for tightness before each use.
- If the mains cable is damaged, it must be replaced by the manufacturer, its customer service department or a similarly qualified person.
- If unusual noises occur during operation, shut down the fan immediately, secure it against restarting and contact the manufacturer, its customer service or a suitably qualified person.
- Before setting up, cleaning or servicing the fan, disconnect the power supply by pulling the plug out of the socket.
- The voltage specification on the rating plate must match the local mains voltage.
- The mains connection to which the fan is connected must comply with the applicable local standards and be installed in accordance with regulations. It must have an earth connection and the fan must be connected to this.
- The fan may only be operated fully assembled and with a protective grille.
- The fan must be operated on a level, stable surface. Never place a pedestal or floor fan on tables or similar objects. Place a table fan on tables and cabinets up to a maximum height of 1.5 metres in such a way that it cannot be accidentally knocked over or pulled down by the cable.
- Route the mains cable so that it does not pose a tripping hazard. Do not route the cable over sharp edges and never crush the cable during installation.
- Do not insert any objects through the protective grille! Remove loose objects that could be sucked in from the intake area before switching on the fan! Keep loose clothing such as scarves with fringes away from the protective grille!
- Select a safe installation location where no objects can be sucked into the protective grille.
- Never use the appliance in places where it could fall or be pushed into water.
- Never touch the fan with wet or damp hands.
- Do not expose the fan to a direct jet of water.
- Never immerse an electrical appliance in water or other liquids.
- Always switch off the fan after use. If you are not going to use it for a longer period of time, unplug it from the mains.
- Do not pull the mains plug out of the socket by the cable. Grip the plug and not the cable when pulling it out.
- Maintenance must be carried out once a year. Check that all screws are tight. Check the mains cable and the protective grille for visible damage. If the mains cable or protective grille are damaged, take the fan out of operation. Contact the manufacturer, its customer service or a suitably qualified person.
- Keep the fan away from heat sources. The minimum distance from radiant heaters and ovens is 1.5 metres.